GAI-Tronics LE200-RM Rack-Mount Page/Party Line Extender User Manual
Page 27

Pub. 42004-392G
M
ODEL
LE200-RM
R
ACK
-M
OUNT
P
AGE
/P
ARTY
®
L
INE
E
XTENDER
P
AGE
25 of 56
e:\standard ioms - current release\42004 instr. manuals\42004-392g.doc
09/14
Series Connection of Page/Party
®
System
Figure 9. Series Connection of Page/Party
®
System
Table 26. Series Connection of Page/Party
®
System Table
Parameter Switch
Configuration
Description
T1 Line Length SW2
Determined by installation distance between each pair of Line Extenders:
A to B
C to D
T1/E1 Clock
Source
SW3-1
SW3-2
Units A and C are the master T1/E1 clock sources:
SW3-1 (open) SW3-2 (open)
Unit B is the slave and uses the T1/E1 clock from Unit A:
SW3-1 (closed) SW3-2 (closed)
Unit D is the slave and uses the T1/E1 clock from Unit C:
SW3-1 (closed) SW3-2 (closed)
LVDS Clock
Source
SW3-3
SW3-4
LVDS clock is used between units B and C:
Unit B - “in” disabled, “out” enabled:
SW3-3 (open) SW3-4 (closed)
Unit C - “in” enabled, “out” disabled:
SW3-3 (closed) SW3-4 (open)
Mute Analog
Lines
SW6-4
Unit C is muted since there is not a Page/Party
®
cable connected:
SW6-4
(closed)