Rules for Interconnecting More than Two Model LE200-RMs
When connecting more than two Model LE200-RMs together, these rules must be followed.
A maximum of two Model LE200-RM pairs can be connected in series when the series connections
are made using Page/Party
®
cable as shown below.
Figure 10. Maximum Series Connections
When the Model LE200-RMs are connected in series, a problem can arise when training the echo
cancellation. If more than one Model LE200-RM is training echo cancellation on a signal line at the
same time, then none of them will train echo cancellation properly. To prevent this, power each Line
Extender one at a time. Wait for the echo cancellation to complete on the first Line Extender before
powering the second.
A maximum of eight pairs of Model LE200-RMs can be connected in parallel. Parallel connections
must be made using the LVDS link and the T1/E1 link as shown below.
Figure 11. Maximum Parallel Connections