beautypg.com

2 ] aborting data transmission, Aborting data transmission, Phase 3 with timeout at the receiving station – Denso BHT-100Q User Manual

Page 198

background image

182

Phase 3 with timeout at the receiving station

If the receiving station receives no subsequent text or normal sequence of DLE EOT
and IDs within 30 seconds after sending a sequence of DLE ACK and IDs, it sends a
sequence of DLE EOT and IDs and aborts the transmission abnormally.

Sending
station

Data text #n

DLE ACK and IDs

DLE EOT and IDs

Receiving
station

30 seconds

[ 2 ] Aborting Data Transmission

Pressing the C key aborts data transmission.

If the C key is pressed during downloading, the BHT transmits a sequence of DLE EOT
and IDs and aborts the file transmission.

If it is pressed during uploading, the BHT transmits the current transmission block
followed by a sequence of DLE EOT and IDs and then aborts the file transmission.

Abnormal
termination

This manual is related to the following products: