Fy fz mx, Hf & lf – Flowserve VTP Wet Pit User Manual
Page 33

VERTICAL TURBINE PUMPS (VTPS) CENTRIFUGAL PUMPS ENGLISH 71569224
– 10-13
Page 33 of 76
flowserve.com
Table of maximum forces and moments allowed on VTP pump flanges
4.7.2.1
Head
Type
Forces &
Moments
Discharge Head Size mm(in.)
100
(4)
150
(6)
200
(8)
255
(10)
305
(12)
355
(14)
400
(16)
460
(18)
508
(20)
610
(24)
760
(30)
915
(36)
W
Fx
0.53
(120)
0.80
(180)
1.13
(255)
1.47
(330)
1.67
(375)
1.78
(400)
Fy
0.67
(150)
1.00
(225)
1.47
(330)
1.83
(410)
2.00
(450)
2.23
(500)
Fz
0.45
(100)
0.67
(150)
0.94
(210)
1.22
(275)
1.34
(300)
1.45
(325)
Mx
0.50
(370)
0.75
(550)
1.06
(780)
1.37
(1015)
1.52
(1125)
1.59
(1175)
My
0.26
(190)
0.39
(285)
0.53
(390)
0.67
(495)
0.74
(550)
0.78
(575)
Mz
0.37
(275)
0.57
(425)
0.77
(570)
1.04
(770)
1.15
(850)
1.18
(875)
HF
&
LF
Fx
1.07
(240)
1.60
(360)
2.27
(510)
2.94
(660)
3.34
(750)
3.56
(800)
4.23
(950)
4.90
(1100)
5.34
(1200)
6.01
(1350)
7.12
(1600)
8.46
(1900)
Fy
1.34
(300)
2.00
(450)
2.94
(660)
3.65
(820)
4.00
(900)
4.45
(1000)
5.12
(1150)
5.79
(1300)
6.23
(1400)
7.12
(1600)
8.46
(1900)
9.79
(2200)
Fz
0.89
(200)
1.36
(300)
1.87
(420)
2.45
(550)
2.67
(600)
2.89
(650)
3.34
(750)
4.00
(900)
4.45
(1000)
4.90
(1100)
5.56
(1250)
6.23
(1400)
Mx
1.00
(740)
1.49
(1100)
2.11
(1560)
2.75
(2030)
3.05
(2250)
3.18
(2350)
3.66
(2700)
4.06
(3000)
4.47
(3300)
5.42
(4000)
6.50
(4800)
7.60
(5600)
My
0.51
(380)
0.77
(570)
1.06
(780)
1.34
(990)
1.49
(1100)
1.56
(1150)
1.83
(1350)
2.03
(1500)
2.51
(1850)
2.71
(2000)
3.25
(2400)
3.80
(2800)
Mz
0.75
(550)
1.15
(850)
1.54
(1140)
2.09
(1540)
2.30
(1700)
2.37
(1750)
2.71
(2000)
3.05
(2250)
3.39
(2500)
4.07
(3000)
4.88
(3600)
5.70
(4200)
TF
(1)
Fx
1.07
(240)
1.60
(360)
2.27
(510)
2.94
(660)
3.34
(750)
3.56
(800)
4.23
(950)
4.90
(1100)
5.34
(1200)
6.00
(1350)
7.12
(1600)
Fy
1.34
(300)
2.00
(450)
2.94
(660)
3.65
(820)
4.00
(900)
4.45
(1000)
5.12
(1150)
5.79
(1300)
6.23
(1400)
7.12
(1600)
8.46
(1900)
Fz
0.89
(200)
1.34
(300)
1.87
(420)
2.45
(550)
2.67
(600)
2.89
(650)
3.34
(750)
4.00
(900)
4.45
(1000)
4.90
(1100)
5.56
(1250)
Mx
1.00
(740)
1.49
(1100)
2.11
(1560)
2.75
(2030)
3.05
(2250)
3.18
(2350)
3.66
(2700)
4.07
(3000)
4.47
(3300)
5.42
(4000)
6.50
(4800)
My
0.51
(380)
0.77
(570)
1.06
(780)
1.34
(990)
1.49
(1100)
1.56
(1150)
1.83
(1350)
2.03
(1500)
2.51
(1850)
2.71
(2000)
3.25
(2400)
Mz
0.75
(550)
1.15
(850)
1.54
(1140)
2.09
(1540)
2.30
(1700)
2.37
(1750)
2.71
(2000)
3.05
(2250)
3.39
(2500)
4.07
(3000)
4.88
(3600)
UF
Fx
CONTACT FLOWSERVE CUSTOMER SERVICE
Fy
Fz
Mx
CONTACT FLOWSERVE CUSTOMER SERVICE
My
Mz
Units: Force (F) in kN (lbf); Moments (M) in kNm (lbf·ft)
1.
Forces and moments shown for TF head are for the discharge flange. For the suction flange, use the values for the next large size
head.
Loads shown are maximum allowable for standard construction. Contact Flowserve if higher values are
required or temperatures are higher than ambient