2.3 Superheat OUTPUT FORM

Outputs

Target SH

(Target Superheat) Indicates what the superheat should be. For

Custom SH Table it is the manufacturer's recommended superheat en-

tered by the tech. For Standard SH Table it is calculated from Return

Wet Bulb and Outdoor Dry Bulb.

Actual SH

(Actual Superheat) Shows the superheat calculated from the

measured suction line temperature and suction line pressure.

Vapor Sat

This is the vapor saturation temperature (boiling point) of the

refrigerant in the evaporator coil. Calculated from SL Pressure.

Suggested Actions

Suggested actions are displayed to correct the

problem. Use the down arrow to scroll down OUTPUT FORM. Be-

cause everything within the system is interdependent, one adjust-

ment can affect the whole system. Tests should be used together such

as Superheat to correct refrigerant charge and Target Evap Exit Temp

to correct airflow across the evaporator coil.

See Sec

(See Section) The section numbers on the OUTPUT FORM refer to

the sections in this manual with more detailed information about each

test.

Keep scrolling through the

OUTPUT FORM to see all

suggested actions.

Superheat OUTPUT FORM.

Superheat OUTPUT FORM continued from above.

The OUTPUT FORM displays

the results of the test.

Compare the Target SH to

the Actual SH. The difference

should be about 5 °F.

Use suggested actions to fix

the problem. Scroll down to

see more.