11. CONFIGURE GPIS FOR DRY/WET

OPERATION

GPIs are set to Dry operation by default. The GPIs may be set for Wet mode

using either a GTP-32 Breakout Panel or using jumpers within the GTP-32. To
configure the jumpers inside the GTP-32:

1) Power down the GTP-32.

2) Using a Phillips screwdriver, remove the top cover from the GTP-32. To do

so, you will need to remove 3 screws from each side of the unit, 2 from

the rear, and 1 from the center of the front of the unit.

3) The GPIO card is on the far right hand side of the unit (if facing the front

panel), behind the GPIO connectors.

4) The jumpers for the GPIs are directly behind the GPI connectors, labeled

J7 through J38. Each set of jumpers for a GPI consists of 4 pins. See the

table below for which GPI corresponds to which jumpers.

5) For Dry operation, set one jumper across pins 2 and 3. Hang the second

jumper off of pin 1.

6) For Wet operation, set one jumper across pin 1 and 2. Set the second

jumper across pins 3 and 4.

7) Once all necessary changes to the jumpers have been made, replace the

top cover and screws on the GTP-32.