D

Watchdog Sample Code

MOV

DX,2Eh

MOV

AL,73h

;Select CR73 (Watch Dog Timer Time-Out Value
Register)

OUT

DX,AL

MOV

DX,2Fh

MOV

AL,02h

;Set CR73 value = 02h => Watch Dog Time = 2
(unit:Min)

OUT

DX,AL

;-------------------------------------------
;(3) Exit extended function mode
;-------------------------------------------
MOV

DX,2Eh

MOV

AL,02h

OUT

DX,AL

MOV

DX,2Fh

MOV

AL,02h

OUT

DX,AL