Power line carrier transmission, Receivers, General principle – Delta Dore 230 CPL DRIVER Installation User Manual
Page 3

- 5 -
- 4 -
Electronic
meter
remote-info
DRIVER CPL
programmer
Mains supply
N
L
N
L
N
N
L
L
TC51089 PLC
receiver
(not supplied)
TC51089 PLC
receiver
(not supplied)
Convectors
zone 1
Convectors
zone 2
Convectors
zone 3
TC51089 PLC
receiver
(not supplied)
GP4 CPL
(optional)
1 DHW output
Electric water
heater
1 2
5 6
Normal
Marche
Défaut
Défaut
OK
Config.
Arrêt
OK
Délestage
CPL
GP4 CPL
ECS
CHAUFFAGE
3 4
In three-phase installations, you must
use a phase coupler to transmit on the
3 phases simultaneously.
N
Ph1 Ph2 Ph3
Phase coupler
Power line carrier transmission
The principle of “PLC” transmissions is to stack an encoded
signal with a higher frequency and weaker amplitude on the
signal present between the live and neutral wires (230 V, 50
Hz).
DRIVER 230 CPL can be used
in blue tariff installations with
an area less than 180 m².
Receivers
They are of the following types:
- TC51089 "Pilot Wire" for controlling 6-order pilot wire
convectors (GIFAM standard).
- X2D PLC reception circuit boards of various convec-
tor manufacturers
- X2D PLC radiators
The quality of the comfort temperature control depends on the
quality of the convector thermostat.
General principle
50 Hz
C
a
rrier
fre
qu
ency
2
3
0 V m
a
in
s
network
Receiver
Transmitter