beautypg.com

Power line carrier transmission, Receivers, General principle – Delta Dore 230 CPL DRIVER Installation User Manual

Page 3

background image

- 5 -

- 4 -

Electronic

meter

remote-info

DRIVER CPL

programmer

Mains supply

N

L

N

L

N

N

L

L

TC51089 PLC

receiver

(not supplied)

TC51089 PLC

receiver

(not supplied)

Convectors

zone 1

Convectors

zone 2

Convectors

zone 3

TC51089 PLC

receiver

(not supplied)

GP4 CPL
(optional)

1 DHW output

Electric water
heater

1 2

5 6

Normal

Marche

Défaut

Défaut

OK

Config.

Arrêt

OK

Délestage

CPL

GP4 CPL

ECS

CHAUFFAGE

3 4

In three-phase installations, you must
use a phase coupler to transmit on the
3 phases simultaneously.

N

Ph1 Ph2 Ph3

Phase coupler

Power line carrier transmission

The principle of “PLC” transmissions is to stack an encoded
signal with a higher frequency and weaker amplitude on the
signal present between the live and neutral wires (230 V, 50
Hz).

DRIVER 230 CPL can be used
in blue tariff installations with
an area less than 180 m².

Receivers

They are of the following types:

- TC51089 "Pilot Wire" for controlling 6-order pilot wire

convectors (GIFAM standard).

- X2D PLC reception circuit boards of various convec-

tor manufacturers

- X2D PLC radiators

The quality of the comfort temperature control depends on the
quality of the convector thermostat.

General principle

50 Hz

C

a

rrier

fre

qu

ency

2

3

0 V m

a

in

s

network

Receiver

Transmitter