9.

Self Test Process

Introduction

The self test process verifies the basic functions of the charger. A
combination of button presses on the charger front panel allows
access to the charger’s Service Mode menu. The self test can then
be selected from the menu.

Self test checks the ability to store data, start/stop switch function,
charge status indicators, audible buzzer test, charger module start-
up as well as the MPC controller’s internal real time clock and
memory.

At least one charger module is required to be fitted for the
self test to complete.

Accessing Self Test

With mains power only applied to the charger ensure that the
LCD displays the start-up screen

Hold down the UP and DOWN buttons simultaneously for 10
seconds until “Test Mode” is displayed as below.

Press the down button to get to the Self-Test option, then press
the ENTER button.

Press the UP button to enable Self Test and press the ENTER
button. In the Cancel/Store menu press the ENTER button to
select Store.

Operating the Self Test Sequence

Press ENTER and in the Switch Test menu Toggle the On/Off
switch. Ensure that the Red Charging lamp in illuminated and
the display reads Red Led Test. Press the UP button to pass
the test.

Connect Battery

48V

Flooded

1000AHr

V29

100A

Test Mode

Disabled

Self Test

Disabled

Self Test

Disabled

Self Test

Enabled

Cancel

Store

Cancel

Store

Self Test

Switch Test
Toggle Switch

Self Test

Red Led Test
ON - Push UP
OFF - Push DOWN