Electrical and signal information, Environmental rating – Daktronics KE-1010-7.6-RG User Manual
Page 60

32
Signal Converter
Electrical and Signal Information
WARNINGS:
• Never install telephone wiring during a lightning storm.
• Never touch uninsulated telephone wires or terminals unless the telphone line has
been disconnected at the network interface.
• Avoid using a telephone (other than a cordless type) during an electrical storm.
There may be a remote risk of electrical shock from lightning.
• To reduce the risk of fire, use only 26AWG or larger telecommunication line cord.
• This product is to be used with UL and c-UL listed computers.
Electrical Ratings
The Signal Converter is rated for either 120 or 240 VAC power in and a maximum draw of 5
watts. Refer to the parts descriptions in Section 2.3.
Power Disconnect
The power cord serves as the disconnect device and the socket outlet must be installed near
the equipment and must be easily accessible.
Parts Listing
The following parts may need replacing during the life of the component.
Servicing should be conducted by qualified personnel only.
Part Description
Part Number
RS-232-422 Signal Converter, 120 V
0A-1127-0255
RS-232-422 Signal Converter, 240 V
0A-1127-0257
Fuse; AGC-1, 1A, Glass Tube 250 V
F-1019
6 Pin Fem, 5 mm, TB Mate, Screw
P-1051
Environmental Rating
The signal converter is made for indoor operations and is rated for indoor use only.