beautypg.com

Mounting multi-section tickers, Figure 8: master-echo installation detail – Daktronics KE-1010-7.6-RG User Manual

Page 11

background image

Display

Distance From Display Top To
Bottom Bracket Attachment Point

KE-1010-16x***-7.62

0’-10 ¼” (260 mm)

KE-1010-24x***-7.62

0’-13 ¼” (337 mm)

KE-1010-2-16x***-7.62

0’-17 ¼” (438 mm)





Mounting Multi-section Tickers

The echo sections are shipped without end caps. Remove the left outer end cap from the
master ticker and attach it to the left-most echo ticker (refer to Figure 8).

Figure 8: Master-Echo Installation Detail


1. Before attempting to connect the sections, check their mounted alignment in relation

to each other. If the alignment is off, then adjust the mounting clips on the back of
the tickers.

2. Hang each section according to the appropriate mounting directions.
3. Refer to Section 3 for routing power and Section 4 for signal installation to each

section.

4. Slide the sections together.
5. Slide the splice bar over the joint(s) between the displays.
6. Tighten the screws (provided in the splices) using a 3/16" hex wrench.

Mechanical Installation

5