3technicalparameters – CREATOR DIG Series Full Digital conference system User Manual
Page 23

CREATOR CHINA
2012-11 WWW.CREATOR1997.COM
16
User's Manual of DIG series Full Digital conference
⑧
DELEGATES——unit interface
4-way
ports
can
be
connected
to
conference unit or junction box
⑨
ALARM——fire alarm port
Expansion interface, this interface can be
used for fire alarm port
⑩
CONTROL SYSTEM——RS-232 serial port
COM IN:Connect to the conference host of
CONTROL SYSTEM,backup the port
COM OUT:Connect to the host of CR-PGM
II central control system or camera tracking host
or backup host to realize the function of automatic
camera tracking
ETHERNET——the network port
1 Ethernet port, connect to the computer to
implement software management functions of the
Conference
OPTICAL——Optical output port
1 optical output interface, corresponding to
the audio digital output⑥ in the rear map.
AUX——RS-232 serial port
It is to extend the functionality , COM IN
backup the conference host AUX port,COM OUT
output。
POWER INPUT——sysyem power input
port
The sysyem power input is 110V/220V AC
2.2.3 technical parameters
Parameter
CR-DIG5200BK
Power Supply
110V/220V AC
Frequency
Response
20-20KHZ
Signal-to-noise ratio
(S/N)
>
80dB
Channel Crosstalk
>
80dB
Total
harmonic
distortion
<
0.05%
Maximum
output
power
350W
Static power
12W
Dimensions
430L x 260W x88H (mm)
Color