beautypg.com

3technicalparameters – CREATOR DIG Series Full Digital conference system User Manual

Page 23

background image

CREATOR CHINA

2012-11 WWW.CREATOR1997.COM

16

User's Manual of DIG series Full Digital conference

DELEGATES——unit interface
4-way

ports

can

be

connected

to

conference unit or junction box

ALARM——fire alarm port
Expansion interface, this interface can be

used for fire alarm port

CONTROL SYSTEM——RS-232 serial port

COM IN:Connect to the conference host of

CONTROL SYSTEM,backup the port

COM OUT:Connect to the host of CR-PGM

II central control system or camera tracking host
or backup host to realize the function of automatic
camera tracking

ETHERNET——the network port
1 Ethernet port, connect to the computer to

implement software management functions of the
Conference

OPTICAL——Optical output port

1 optical output interface, corresponding to

the audio digital output⑥ in the rear map.

AUX——RS-232 serial port

It is to extend the functionality , COM IN

backup the conference host AUX port,COM OUT
output。

POWER INPUT——sysyem power input

port

The sysyem power input is 110V/220V AC

2.2.3 technical parameters

Parameter

CR-DIG5200BK

Power Supply

110V/220V AC

Frequency
Response

20-20KHZ

Signal-to-noise ratio
(S/N)

80dB

Channel Crosstalk

80dB

Total

harmonic

distortion

0.05%

Maximum

output

power

350W

Static power

12W

Dimensions

430L x 260W x88H (mm)

Color

dark gray