Cadac F-Type User Manual
Page 42

2-14
Central Control Module 7896
F-Type
Revision F2005-2
■
■
■
■
If there is a fault, a fault code is displayed indicating the type of fault.
This test automatically returns to “Test comms?”.
K,
6KRZ#7LPH
In the system menu, select “
Test Routines?” using the Up or Down arrow button.
The display shows “
Test Routines?”.
■
■
■
■
Press [
↵
], followed by the Down Arrow button, until the display shows “
Show
Time?”
■
■
■
■
Press [
↵
]. The display shows the time as set in the PC.
Press [Esc] to return to the system menu or Down arrow to perform next test.
L,
6KRZ#'DWH
In the system menu, select “
Test Routines?” using the Up or Down arrow button.
The display shows “
Test Routines?”.
■
■
■
■
Press [
↵
], followed by the Down Arrow button, until the display shows “
Show
Date?”
■
■
■
■
Press [
↵
]. The display shows the date as set in the PC.
Press [Esc] to return to the system menu or Down arrow to perform next test.
NOTE: The Time/Date do not increment when power is removed from the console.
They rely upon SAM updating them when communications are first established.
M,
9LHZ#(UURU#/RJ
In the system menu, select “
Test Routines?” using the Up or Down arrow button.
The display shows “
Test Routines?”.
■
■
■
■
Press [
↵
], followed by the Down Arrow button, until the display shows “
View Error
Log?”
■
■
■
■
Press [
↵
]. The display lists the time and date of errors/events.
■
■
■
■
Select
Time/Date with the arrow keys.
■
■
■
■
Press the Right arrow key to display the type of error.
■
■
■
■
Press the Left arrow key to get back to the list of time/date.
NOTE:
Some messages are included in the error log for debugging purposes that
are not in themselves errors. Examples are Time/Date reset or Host is Séance on
the display are not errors.
Press [Esc] to return to the system menu.
N,
&OHDU#(UURU#/RJ
In the system menu, select “
Test System?” using the Up or Down arrow button.
The display shows “
Test System?”.
■
■
■
■
Press [
↵
], followed by the Down Arrow button, until the display shows “
Clear
Error Log?”
■
■
■
■
Press [
↵
↵↵
↵
]. The log is cleared and the event is entered in the Error log.
This test automatically returns to the system menu.