3 test routines – Cadac F-Type User Manual
Page 40

2-12
Central Control Module 7896
F-Type
Revision F2005-2
51816
7HVW#5RXWLQHV
See below for options.
D,
6\VWHP#WHVW#²#7HVW#IDGHUV#4
In the system menu, select “
Test Routines?” using the Up or Down arrow button.
The display shows “
Test Routines?”.
■
■
■
■
Press [
↵
], followed by the Down Arrow button, until the display shows “
Inc All
Faders?”
■
■
■
■
Press [
↵
]. The display changes to “
Testing Faders”.
The group number display on each of the channels faders increments from 0 to C,
before returning to zero.
At the same time on the channel, the following automated switches cycle:
MIC 1 ON
MIC 2 ON
PAN
LP FILTER
HP FILTER
EQ 1 IN
EQ 2 IN
INS
At the end of each cycle:
VCA MUTE
NEXT TIME
AUX
NEXT TIME
VCA MUTE & AUX
Meanwhile the groups automated switches cycle:
INS A
INS B
MAT PRE
SUB INS
At the end of each cycle the DC Master MUTE turns ON and OFF.
Press [Esc] to return to the system menu or Down arrow to perform next test.
E,
6KRZ#0)GU#'DWD
In the system menu, select “
Test Routines?” using the Up or Down arrow button.
The display shows “
Test Routines?”.
■
■
■
■
Press [
↵
], followed by the Down Arrow button, until the display shows “
Test fad-
ers 2?”
These tests are for the operation of Motor faders only. If there are no Motor faders in
the console, skip these tests and go to 2.3.11 “
Test keys”.
■
■
■
■
Press [
↵
]. Check that all Motor faders are responding and that their positions are
correctly displayed.
■
■
■
■
Using the Left and Right arrow keys, select the fader to test. (Press [
↵
] to go
directly to the channel faders.)
The display shows: “Group 1:0000 00”
The left and right arrow keys may be used to select each fader in turn, group 1
through 16, then channel 1 upwards. The numbers displayed after the colon repre-
sent the raw fader data. If you are experiencing difficulties, please contact CADAC.