5 main and extension frame power connections, 5 main and extension frame power, Connections – Cadac F-Type User Manual
Page 14

1-6
Connecting the mixer systems
F-Type
Revision F2005-2
41618
0DLQ#DQG#H[WHQVLRQ#IUDPH#SRZHU#FRQQHFWLRQV
See fig 1-4 below for schematics of the frames power connections.
1.
Using a short U-LINK cable (supplied), connect one of the outputs on the ±18V
PSU to one of the outputs on the +13V/+48V PSU in the “SYSTEM 1" power
supply rack. This operation “links” the d/c outputs on both power supply units in
the rack so that ±18V, +13V and +48V is available on all remaining output con-
nectors on either power unit.
2.
Connect the second short “U-LINK” cable (supplied) between the ±18V PSU and
the +13V/+48V PSU’s in the “SYSTEM 2" power supply rack.
3.
Connect a PSU cable between the “SYSTEM 1" rack and the “PSU SYSTEM 1"
connector on the MAIN FRAME.
4.
Connect a PSU cable between the “SYSTEM 2" rack and the “PSU SYSTEM 2"
connector on the MAIN FRAME.
5.
Connect a PSU cable between the “SYSTEM 1" rack and the “PSU SYSTEM 1"
connector on the EXTENSION FRAME 1.
6.
Connect a PSU cable between the “SYSTEM 2" rack and the “PSU SYSTEM 2"
connector on the EXTENSION FRAME 1.
7.
Repeat procedures 5. and 6. for EXTENSION FRAME 2 (a 3 frame console).
FIG 1-6. Power connections