5 switching on, 1 system power-up procedure, 2 system power-down procedure – Cadac C-Type User Manual
Page 13: Switching on -7

Connecting the mixer systems
1-7
Revision C2005-2
C-Type
418
6ZLWFKLQJ#21
41814
6\VWHP#SRZHU0XS#SURFHGXUH
CADAC consoles are designed to work continuously with two power supplies - ‘main’
and ‘backup’. The ‘main’ power supply is designated PSU 1. The ‘backup’ power
supply pair is designated PSU 2.
On each power supply, turn all AC input switches to the ON-position.
Start the PSU by pressing and holding the START-buttons until you hear the relay
click. Repeat for PSU 2. .
41815
6\VWHP#SRZHU0GRZQ#SURFHGXUH
1.
Switch off the AC mains supply to PSU system 1.
2.
Switch off the AC mains supply to PSU system 2.