27

The global configuration screen contains settings for the calibration of the travel speed and options

that affect the entire system. It allows you to set the language, administrator PIN number, default

units, minimum gas flow, IP addresses, auto reverse, data logging and water cooler.

Figure 7.0

7.1 Travel Speed Offset – The travel speed offset should be set up before welding with the

machine. This involves the drive moving a set distance. Follow the onscreen guides to

calculate the offsets. Mark the initial position of the tractor on the pipe. Click Travel. Wait for

the machine to stop moving. Enter the distance traveled (in inches) into the popup prompt.

The stop button below this box will stop the drive if necessary. The calibration is always

performed in inches.

7.2 Set Piper IP – Please See SECTION 8.0 – NETWORKING for details.

7.3 Language

– The text displayed within each of the screens of the Piper Plus is based on

standard .xml files. It is possible to modify these files so the screens display text in most

standard script languages. Contact Bug-O Systems factory for details.

7.1

7.2

7.3

7.4

7.5

7.6

7.7

7.8

7.9

7.10

7.11

SECTION 7.0 GLOBAL CONFIGURATION