28 ...... section 7.0 global configuration – BUG-O Systems Piper-Plus User Manual
Page 27

27
The global configuration screen contains settings for the calibration of the travel speed and options
that affect the entire system. It allows you to set the language, administrator PIN number, default
units, minimum gas flow, IP addresses, auto reverse, data logging and water cooler.
Figure 7.0
7.1 Travel Speed Offset – The travel speed offset should be set up before welding with the
machine. This involves the drive moving a set distance. Follow the onscreen guides to
calculate the offsets. Mark the initial position of the tractor on the pipe. Click Travel. Wait for
the machine to stop moving. Enter the distance traveled (in inches) into the popup prompt.
The stop button below this box will stop the drive if necessary. The calibration is always
performed in inches.
7.2 Set Piper IP – Please See SECTION 8.0 – NETWORKING for details.
7.3 Language
– The text displayed within each of the screens of the Piper Plus is based on
standard .xml files. It is possible to modify these files so the screens display text in most
standard script languages. Contact Bug-O Systems factory for details.
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
7.10
7.11
SECTION 7.0 GLOBAL CONFIGURATION