Besa Lighting Rail Connectors (Monorail Component) User Manual
Save these instructions, Important safety instructions, Installation guide

INSTALLATION GUIDE
Model DCONN Isolating Rail Connector
(For use with Besa low voltage lighting systems only)
DCONN, Rev.2 2-09
6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
IMPORTANT SAFETY INSTRUCTIONS:
A) Read all instructions.
B) Do not conceal or extend exposed conductors through a building wall.
C) Do not install this system in wet locations.
D) For low voltage exposed insulated conductor systems required by 30.1(c) do not install
any part of this system less than 7 feet (2.2m) above the floor.
E) To reduce the risk of fire and burns, do not install this lighting system where the exposed
bare conductors can be shorted or contact any conductive materials.
F) To reduce the risk of fire and overheating, make sure all connections are tight.
G) Do not install any luminaire closer than 6 inches (15.25 cm) from any curtain, or similar combustable materials.
H) Turn off electrical power before modifying the lighting system in any way.
SAVE THESE INSTRUCTIONS
Isolating Rail
Connector
Rail Section
Philips
Set Screw
1. Loosen set screw on the Isolating Rail Connector,
then carefully slide the Rail Sections into each end.
2. Retighten Set Screw to secure Rail Sections together.