beautypg.com

Besa Lighting Amelia 12 / 15 / 18 (120V Pendants) User Manual

Installation guide

background image

INSTALLATION GUIDE

Model 1KS Series -06 (Med. Base Pendant Set 120V)

1KS.06, Rev.2 12-11

6695 Taylor Rd. Blacklick, OH 43004

www.besalighting.com

Caution: Turn off power to electrical box before installing

1. Carefully unpack parts. Remove

the Canopy (A) from the Mounting

Plate by unscrewing the three (3)

Retainers. Fully remove the

Retainers from the threaded

nipple, then pull the canopy

from the Mounting Plate.

A

B

2. Install the provided Mounting

Screws (C) into the Outlet Box,

leaving 1/4” of threading as shown.

Pull the House Wires from the

Outlet Box and extend through

the center opening in the Mounting

Plate (D).

C

D

Align the circular openings of

the Keyhole Slots (E) with the

Screws then push the Mounting

Plate up over the Outlet Box.

Rotate the Mounting Plate and

secure with Mounting Screws.

E

3. Shorten the three (3) cables to

the desired length by pushing

the cable up through the Cable

Retainers (F). Trim off the excess

cable length, leaving about 3”

of slack for final adjustment.

To lower the cables, push the

Cable Retainer up, which will

release the cable and allow it

to be lowered.

4. Prior to installing the canopy, the

cord length must be adjusted.

Loosen the set screw on the Strain

Relief (G), the feed the cord up

through until reaching the desired

length. Tighten the set screw until

the cord is firmly in place.
NOTE:

For a curvy cord

appearance, leave about 25%

slack for shaping of the cord

Once the cord length has

been adjusted, the cord must

be shortened above the canopy.

When shortened, insure that

there is 6” or more of wire

above the canopy.

6. Prior to replacing the canopy,

push the house wiring and

wirenuts up through the center

opening and into the Outlet Box.

Push the canopy up tight to the

ceiling as shown, then secure

with the Retainers. Do not

overtighten the retainers, as this

could make it difficult to remove.

G

F

5. Attach the the bare copper fixture

ground wire and bare (or green

striped) ground conductor from the

cord to the supply ground and secure

with provided Wire Nut Connector (H).

Connect the cord conductors from

the fixture cord to the supply

conductors with Wire Nut Connectors

(J) as shown: Cord conductor with

white stripe to white supply wire and

clear cord conductor to black supply

wire.
NOTE:

When using the clear style cord,

it is advised that the installer

confirm the polarity per

instructions on the next page.

H

Clear

White Stripe

Bare or Green Stripe

J

Replacement parts for this 120V Voltage Pendant Set are as follows:

#T1KS100-SN.06 - 100W 10’ clear cordset and 3 support cables with Nickel Hardware

For 15’ cordset, place “L” after metal finish.

This manual is related to the following products: