Monorail system ordering guide, Select the appropriate power supply for your needs, Select your rail and fittings

background image

12 v monor

ail

R

ail
&

Spo
tlight

S

Besa Lighting Co., Inc. • 6695 Taylor Rd. • Blacklick, OH 43004 • tel 614-475-7046 • fax 614-475-7048 • www.besalighting.com

m o n o r a i l s y s t e m

o r d e r i n g g u i d e

monorail system

ordering guide

Covering almost any design need, our system components have

been specifically designed to simplify the ordering process.

Follow these 3 simple steps to determine the components you

need (listed on pgs. 10-11).

Then choose your rail-ready spotlights and pendants from the

following pages, using series #RSP (for spotlights) or #RXP (for

pendants).

Total Load Suggestions
• For all 50W elements,

simply multiply QTY x50

• For elements with

different lamp ratings,

simply ADD all the

wattages

Add finish choice to your part numbers:

-BR

Bronze

-SN

Satin Nickel

For optimal performance,

it is best to locate the feed

near the center of the rail.

Step

1

Select the appropriate power supply for your needs:

A) Determine total load

QTY Desired Light Elements = _________ x Wattage = _________ Total Load

B) When the Power Supply is local to the monorail

(surface-mounted)

Total Load (Watts) _________ ÷ 60 = _________

(QTY)

R12-SA60LED

LED Surface Power Supply

OR

Total Load (Watts) _________ ÷ 150 = _________

(QTY)

R12-SA150

Electronic Surface Transformer

OR

Total Load (Watts) _________ ÷ 300 = _________

(QTY)

R12-SM300

Magnetic Surface Transformer

C) When the Power Supply is remote

Total Load (Watts) _________ ÷ 300 =_________

(QTY)

R12-RM300

Magnetic Remote Transformer

PLUS

_________

(QTY)

R12-REMFC

Remote Feed Canopy

(required for each 300W of remote power supply)

Step

2

Select your rail and fittings:

A) Rail Sections

Total Desired Length (in Ft) _________ ÷ by 8 = _________

(QTY)

R12-RAIL8

8 Ft Sections

(if needed to achieve desired length)

_________

(QTY)

R12-RAIL4

4 Ft Sections

B) Live Rail Connectors

QTY Rail Sections _________ – QTY Power Supplies = _________

(QTY)

R12-ICONN

Live Rail Connectors

OR

QTY Rail Sections _________ – QTY Power Supplies = _________

(QTY)

R12-LCONN

Live “L” Rail Connectors

C) Isolating Rail Connectors

QTY Power Supplies Per System _________ – 1 = _________

(QTY)

R12-DCONN

Isolating Rail Connectors

(may be 0 if qty of power supplies = 1)

D) End Caps

QTY Systems Ordered _________ x 2 = _________

(QTY)

R12-NDCAP

End Caps

Step

3

Select the right support hardware:

A) For Standard Flat Ceiling

(rigid standoffs)

Total Length of System _________ ÷ 2 =

(QTY)

(QTY)

R12-STAN1

Rigid Standoffs

B) For Sloped Ceiling

(swivel standoffs)

Total Length of System _________ ÷ 2 = _________

(QTY)

R12-STAN2

Swivel Standoffs

(sloped ceiling use typically requires extension posts, see at right)

C) For High Ceiling

(adjustable cable support)

Total Length of System _________ ÷ 2 = _________

(QTY)

R12-CBL60

Adjustable Cable Supports

QTY Power Supplies per system = _________

(QTY)

R12-FLX60

Flexible Feed Cable

D) To Increase Height of Standoffs

QTY of Rigid or Swivel Standoffs _________ = _________

(QTY)

R12-EXT06

6” Extension Posts

(choose extension length)

_________

(QTY)

R12-EXT12

12” Extension Posts

_________

(QTY)

R12-EXT18

18” Extension Posts

Note: 600W Remote

Magnetic Transformer
• 600W Magnetic Remote

Power Supply can be

used to replace 2x 300W

power supplies

Rail Length Suggestions
• For rail sections, round

up or add 4’ length(s)

• Curves require extra

rail, we suggest adding

20% to the total

Standoff Suggestions
• A surface transformer

often acts as a support,

which may reduce the

qty of rigid standoffs

by one

• On sloped ceilings,

typically the height

of the standoffs will

vary, so extension

posts may be required

This manual is related to the following products: