Sm300, rev5, Important safety instructions, Save these instructions – Besa Lighting Surface Power Supply (Monorail Component) User Manual
Page 3: Installation guide

6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
INSTALLATION GUIDE
Model SM300 Surface Magnetic Transformer
(For use with Besa low voltage lighting systems only)
SM300, Rev.5 2-09
Caution: Turn off power to electrical box before installing
IMPORTANT:
Do NOT use a standard incandescent dimmer.
Use a magnetic low voltage dimmer only.
Installation of Transformer:
1. Loosen Set Screw on the Rail Adapter of the Canopy.
2.
Raise the Monorail into the Rail Adapter, then tighten
Set Screw. If needed, the opening of the Rail Adapter
can be increased by loosening the Allen Screws,
then retighten.
3. Turn on power to system.
Operate system for 5 minutes, then verify that
the connections are running cool to the touch.
Installation of Monorail:
Junction
Box
1. Extension Wires are supplied to connect
the Building Wires to the Transformer leads.
Connect white neutral wire to the white wire,
and black hot wire to black wire with wire nuts.
The Ground Wire may be green or bare copper,
connect it to the green wire and mounting
crossbar ground wire using a wire nut.
2. Carefully pass the Extension Wires through
the center hole of the supplied Crossbar/Threaded
Nipple assembly, then secure crossbar to the
Junction Box with Mounting Screws.
3. Raise the Transformer Assembly onto
the Threaded Nipple, then secure with
the Washer, Star Washer and Hex Nut.
4. Connect the Extension Wires to the Transformer
Leads with wirenuts. Connect white neutral wire
to the white wire, and black hot wire to black wire
with wire nuts. Then connect the grounding wires
to the green wire.
5. Install the Transformer Canopy by positioning onto
the Transformer Assembly and securing with
the three Canopy Screws.
6. The monorail can now be connected to the canopy.
NOTE:
For applications where the monorail is not directly
below the canopy, utilize the flexible feed provided.
Hex Nut
Transformer
Canopy
Mounting
Screws
Grounding
Wires
Extension
Wires
Threaded
Nipple
Crossbar
Transformer
Assembly
Transformer
Leads
Grounding
Wires
Canopy
Screws
Green
Green
Green
Canopy
Monorail
Rail Adapter
Allen Screw
Set Screw
IMPORTANT SAFETY INSTRUCTIONS:
a. Read all instructions.
b. Do not conceal or extend exposed conductors through a building wall.
c. Do not install this system in wet locations.
d. For low voltage exposed insulated conductor systems required by 30.1(c) do not install any part
of this system less than 7 feet (2.2m) above the floor.
e. To reduce the risk of fire and burns, do not install this lighting system where the exposed bare
conductors can be shorted or contact any conductive materials.
f. To reduce the risk of fire and overheating, make sure all connections are tight.
g. Do not install any luminaire closer than 6 inches (15.25 cm) from any curtain, or similar
combustable materials.
h. Turn off electrical power before modifying the lighting system in any way.
i. Do not connect to an ungrounded supply.
SAVE THESE INSTRUCTIONS
Circuit
Breaker