beautypg.com

21qp,rev3 (target), Fixture installation guide – Besa Lighting Pera 6 (Mini Pendants 12V) User Manual

Page 4

background image

FIXTURE INSTALLATION GUIDE

All electrical connections and the installation of this fixture must be in agreement with local codes,

ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).

Do not connect this fixture to an electrical system that does not provide a means for equipment grounding.

Model T21QP (Low Voltage Quick-Connect Canopy)

21QP, Rev.3 6-10

Caution: Turn off power to electrical box before installing

6695 Taylor Rd. Blacklick, OH 43004

www.besalighting.com

1. Carefully remove parts from package.

2. Connect the house ground wire to the Bare Copper Lead and secure with wirenut provided (A).

Connect the electrical leads from the Transformer to the house supply wires, black to black and

white to white, and secure with wirenuts provided (B).

3. Align the Openings (C) on the Canopy with the Threaded Holes (D) on the Supply Box.

Push the Canopy over the Supply Box until the Canopy is flush to the ceiling, then secure with the

Threaded Screws (E). It is important that the Supply Box is deep enough to allow for the Transformer.

4. Place the Decorative Cover (F) over the threaded nipple on the canopy, then attach the Besa

Quick Connect Element (G). The Besa Quick Connect Element is furnished separately.

5. With the power still off, insert bulb of not more than the labeled wattage on the Quick Connect Element.

6. Turn power on.

A

B

C

D

E

F

G

Note:

For optimum performance,

an electronic low voltage dimmer

should be used. Installation of a

low voltage dimmer requires a

neutral lead in the switch box for

proper wiring.

If employing a standard incandescent

dimmer, low levels of noise (”buzzing”)

may emanate from either the dimmer or

transformer. This is usually caused by

dimmer/transformer incompatibility and

may be eliminated by simply replacing

the dimmer.