beautypg.com

Online verifier parameter list – Avery Dennison Monarch 9864 Verifier User Manual

Page 9

background image

Online Verifier Parameter List

For normal operation, set all parameters to their default values except ANSI
Symbolgrade
. Set ANSI Symbolgrade to the value you need and the verifier
automatically uses the correct setting for all other parameters as specified by the ANSI
grade.


Menu Parameter

Description

OLV PARAMETER

Verify mode

Default: All Bar codes
All bar codes are being checked according to the limits
set at the printer.
Note: The EasyPlug formats do not have to be

adapted when using this option.

Easyplug select.
Only bar codes that have the "V" set in the command
option are verified.

OLV PARAMETER

Cancel printing

Default: Disabled
The printer reports any bar code errors on the display.
Enabled
The printer reports any bar code errors on the display
and prints a diagonal pattern over any bad bar code.

OLV PARAMETER

OLV mode

Default: Fast
The printer prints and verifies in real time. There is no
reduction in throughput.
Slow
The printer prints the label, then feeds the label to the
verifier. After verifying, the label feeds back into the
printer to resume printing. This reduces throughput.

OLV PARAMETER

Ref Decode

Default: No Test
The bar code does not have to be decodable.
Pass
The bar code must be decodable.

OLV PARAMETER

Decodability

Default: -1
No checking
0-100
The value must equal or exceed this limit.

OLV PARAMETER

Modulation

Default: -1
No checking
0-100
The value must be higher than or equal to the set limit.

OLV PARAMETER

Defects

Default: -1
No checking
0-100
The value must be lower than or equal to the set limit.

OLV PARAMETER

Edge Contrast

Default: -1
No checking
0-100
The value must be higher than or equal to the set limit.

OLV PARAMETER

Rmin/Rmax

Default: -1
No checking
0-100
The value must be lower than or equal to the set limit.

9