#G Peripheral Parameter Menu
#G-----------------------------------------------------------------------------
#PC2512/1

#G Rewinder Motor : Generation 2

#PC2501/0

#G Current mode : Table values

#PC2502/100

#G Min rew. current : 100

#PC2503/250

#G Max rew. current : 250

#PC2504/170

#G Min rew. current : 170 %

#PC2505/170

#G Max rew. current : 170 %

#PC2506/0

#G Start rew. curr. : 0 %

#PC2507/30

#G Start cur. len. : 30 mm

#PC2508/95

#G Pullback current : 95

#PC2509/50

#G Back diameter : 50 mm

#PC2510/0

#G Break current : 0

#PC2511/120

#G Break diameter : 120 mm

#G-----------------------------------------------------------------------------
#G Dispenser Interface
#G-----------------------------------------------------------------------------
#PC3001/0

#G Interface type : USI interface

#PC3002/0.0

#G Start delay : 0.0 mm

#PC3003/0

#G Start print mode : Pulse falling

#PC3004/0

#G End print mode : Mode 0

#PC3005/0

#G Reprint signal : Disabled

#PC3006/1

#G Ribbon signal : Enabled

#PC3007/0

#G Material signal : Disabled

#PC3013/60.0

#G Diam. mat. end : 60.0 mm

#PC3008/0

#G Feed input : Standard

#PC3012/0

#G Pause input : Standard

#PC3009/0

#G Start error stop : Off

#PC3010/1

#G Internal inputs : Enabled

#PC3011/0

#G Apply mode : After start sig.

#G-----------------------------------------------------------------------------
#G Textile Parameter Menu
#G-----------------------------------------------------------------------------
#PC3301/1

#G Changelabel Mode : Always at jobend

#PC3302/1

#G Changelab Print : With print

#PC3303/10

#G Changelab Length : + 10 mm

#PC3304/1

#G Label Eject Mode : Yes, at job end

#PC3305/0

#G Head lift autom. : after 0 labels

#G-----------------------------------------------------------------------------
#G Applicator Parameter Menu
#G-----------------------------------------------------------------------------
#PC3101/0

#G Applicator type : LTP - LTPV

#PC3102/0

#G Apply mode : After start sig.

#PC3110/2

#G Start print mode : Pulse rising

#PC3103/0

#G Start error stop : Off

#PC3104/0

#G APSF sensor res. : 0 pulses/m

#PC3105/0.0

#G Start delay : 0.0 mm

#PC3106/1

#G Dwell time : 1 ms

#PC3107/1

#G Blow on time : 1 ms

#PC3108/0

#G Restart delay : 0 ms

#PC3109/2000

#G Position timeout : 2000 ms

#PC3212/0

#G Start error stop : Off