Power Requirements

Vibration

1.0g from 5 to 100 Hz and back to 5 Hz at a rate of
0.1 octave/minute

5-20 Hz @ 0.01 g

2

/Hz

20-200 Hz @ -3.0 dB/octave
Random 5-20 Hz @ 1
m

2

/Sec

3

Random 20-200 Hz @ -3
m/Sec

2

Shock

Half-sine, 11 m/Sec, 30mSec/sec

2

Blade level packaging
Half-sine, 6 mSec at 180
m/Sec

2

Free Fall

1,200 mm (Packaged) /all
edges and corners
1.0m (Packaged) per ETSI
300 019-2-2 (Blade level
packaging)
25mm (unpackaged) per
GR-63-CORE

Table 2-1 Environmental Requirements (continued)

Requirement

Operating

Non-Operating

Table 2-2 Power Requirements

Requirement

Operating

Power supply

Provided by the server blade

Maximum power consumption

14.2 W