Sorensen SLM-1 Chassis

GPIB/RS-232 Programming

Command Syntax:
All Modules:

[GLOB:] LEVE {SP}{HIGH|LOW}{NL}

Description:
LEVE LOW is Set LOW current level in CC mode, LOW resistance level in CR mode, or
LOW voltage level in CV mode at the active load channel.
LEVE 1 is Set HIGH current level in CC mode, HIGH resistance level in CR mode, or HIGH
voltage level in CV mode at the active load channel.

PRESET ON/OFF

Purpose:
Set the upper or lower digit multi-function meter to display the programming load level.
Command Syntax:
All Modules:

[GLOB:]PRES{SP}{0|1|OFF|ON}{NL}

Description:
GLOB:PRES ON is set all the load module in the SLM chassis to preset on status.

MODE

Purpose:
Select the operating mode of Electronic load module.
Command Syntax:
All Modules:

[GLOB:]MODE{SP}{0|1|2|3|CC|CR|CV|CP}{NL}

Description:
GLOB:MODE CC ; set the presently operating mode to Constant Current mode for all load
module in the SLM chassis.
MODE CV ; set the presently operating mode to Constant Voltage mode.
MODE 1 ; set the presently operating mode to Constant Resistance mode.
MODE CP ; set the presently operation mode to Constant Power mode.
Note

:

MODE CV is available in DC loads only.
MODE CP is available in DC, single input loads only.

CLEAR status register

Purpose:
CLEar the PROT and ERR status byte registers.
Command Syntax:
All Modules:

CLER{NL}

Description:
CLER ; clear the PROT and ERR status byte register, the PROT and ERR status byte
register will indicate “0” after executing the CLER command.

STORE

Purpose:
STORE the load level and load status into the memory of the SL-series electronic LOAD.
Command Syntax:
SLM DC, SLD Modules: STOR{SP}{m[,n]}{;|NL}
SLM AC Modules:

STOR{SP}{m}{;|ML}

Description: