Hannel, Alibration, 3 channel b calibration – AMETEK SL Series Software User Manual

Page 22

background image

Calibration Procedure

Elgar Electronics Corporation

2.3 CHANNEL

B

CALIBRATION

Press CHAN to light the B LED.

Press both MODE and LIMIT simultaneously to enter calibration mode. Initial
default mode is Constant Current (CC) Mode.

2.3.1

C

ONSTANT

C

URRENT

(CC) M

ODE

C

ALIBRATION

, C

HANNEL

B

Make the appropriate connections per Figure 2-13, Figure 2-14 or Figure 2-15
for the load module being calibrated.

Note: refers to both SLD-60 and SLD-80.

Figure 2-13. Channel B CC Mode Connections for SLD-60 Calibration

Figure 2-14. Channel B CC Mode Connections for SLD-61 Calibration

Figure 2-15. Channel B CC Mode Connections for SLD-62 Calibration

2-14

SLD Calibration Manual