Sorensen SFA Series

Operation

Designator

Schematic

Symbol

Electrical

Chars.

Functional Description

8 Not

Used

9 Not

Used

10 IP

5V

Zin ~ 10k

Remote current programming using a 0-5 VDC source.
Do not exceed 13.3 VDC.

11

ISET

*

Zout ~

100

0-5 VDC (0-100%) front panel current control monitor output.
Minimum load resistance 10k

Ω.

12 SENSE

~ 1000

Ω to

neg (–)

output

terminal

Remote Sense (–) on 60 volts output units.
(For new installations, use J3, recommended only for
backward compatibility in existing systems.)

13 SENSE

+

~ 1000

Ω to

pos (+)

output

terminal

Remote Sense (+) on <60 volts output units.
(For new installations, use J3, recommended only for
backward compatibility in existing systems.)

14

ISO

TTL/CMOS

Zin ~ 2.2k

Isolated TTL/CMOS on/off control. A high state TTL/CMOS voltage
turns on the power supply, and a low state or open connection turns
the supply off.

15 Not

Used

16 IP

10V

Zin ~ 20k

Remote current programming using a 0-10 VDC source.
Do not exceed 25 VDC.

17 FAULT

Zout ~

100

Fault state output. A high state (approximately +10 VDC)
indicates a converter, temperature or bias supply fault, and
the LED on the front panel will illuminate.

18 S/D

FAULT

Zout ~

100

Shutdown fault. This terminal goes to high state in the event
of converter, temperature, overvoltage or bias supply fault. A
7 VDC to 13.3 VDC signal can be applied to this pin to
shutdown the output of the unit. An 8 VDC minimum output
signal is provided into a 10 k

Ω minimum load, in the event of

an internally generated shutdown.

19 V

MON

Zout ~

100

Output voltage monitor. 0-10 VDC equals to 0-100% rated
voltage. Minimum load resistance 10k

Ω.

M550292-01 Rev G