beautypg.com

Sfa series voltage and current specifications, Sfa series voltage and current specifications -4 – AMETEK SFA Series User Manual

Page 22

background image

Sorensen SFA Series

Overview

Parameter Specification

Efficiency

87% typical at full load, nominal line

REMOTE PROGRAMMING

Accuracy

C

ONSTANT

C

URRENT

±0.8% of full-scale output

Overcurrent Protection

±1% of full-scale output

Resistive Control Input

C

ONSTANT

C

URRENT

(0-100%)

0–5 k

Voltage Control Input

Constant Current (0-100%)

0–5 VDC or 0–10 VDC

Overcurrent Protection (OCP)
(0-110%)

0–5.5 VDC

Remote Sensing

Terminals are provided to sense output voltage at point of load
for accurate voltage measurement.

Overvoltage Protection

Fixed at approximately 110% of the rating compliance voltage.
Reset requires cycling the front panel standby power switch
off/on

ISOLATED ANALOG CONTROL (OPTION)

Input to Output Isolation

600 V
Compliant with maximum terminal float voltage. Recommended
operation under SELV normal conditions.
(Standard Non-isolated Analog programming 300V maximum.
Recommended operation under SELV normal conditions).

1.2.3

SFA

S

ERIES

V

OLTAGE AND

C

URRENT

S

PECIFICATIONS

Ratings

Voltage

5 kW

10 kW

15 kW

20 kW

25 kW

30 kW

0-60V 0-83A 0-167A 0-250A 0-333A 0-417A 0-500A

0-100V 0-50A 0-100A 0-150A 0-200A 0-250A 0-300A

0-160V 0-31A 0-63A 0-94A 0-125A 0-156A 0-188A

NOTE: Contact factory for availability on specific models

1-4

M550292-01 Rev G