Operation
Auto Sequencing

68

Operating Manual for Multichannel Functionality (GPIB-M)

Example:

Set a slew rate of 100V/10s for a 100V-60A power supply. This slew rate is 1V/0.1s,
which is within the acceptable range.

Send the commands:

“:VOLT:SLEW:STEP 1”

, and

“:VOLT:SLEW:INT 100ms”

Using smaller steps will result in a smoother curve.

Identification

Query

The identification query command returns a string that states the manufacturer,
model, serial number, and firmware revision.

*IDN?

may return “Xantrex, XFR 10-120, 100000, 3.000/0/0/0000.

Option

Identification

Query

*OPT?

or

SYST:OPTion?

The option identification query returns a string listing any reportable options that are
installed in the power supply. Reportable options are GPIB and CANbus, but may
include others in the future. A zero will be returned if no options are installed.

Example:

*OPT?

may return "GPIB, CANBUS" to indicate that both the GPIB and CANbus

(Multichannel/Current Share) options are installed.

SCPI Version

Query

SYST:VERS?

will return the SCPI version to which the unit complies (for example 1997-0).