beautypg.com

AMETEK HPD Series GPIB-Multichannel User Manual

Page 59

background image

Operation

Power Supply Operation

55

User Settings

(Save and

Recall)

If you have a frequent or constant need for a specific voltage and current output, you
can save these setpoints in the power supply’s memory as a user setting. Once a
setting is stored, it remains in the power supply’s memory after the unit is powered
off.

Ten user setting memory locations are available, and each saves the following
parameters:

Voltage setpoint

Current setpoint

Over-voltage protection setpoint (OVP)

Under-voltage protection setpoint and shutdown configuration (UVP)

Over-current protection setpoint and shutdown configuration (OCP)

Under-current protection setpoint and shutdown configuration (UCP)

Foldback protection mode and delay settings

AC Off auto recovery configuration (ACO)

OTP auto-recovery configuration

Aux line configuration

Voltage and current soft limits

Triggered setpoints and trigger source

To store (save) settings:
*SAV

or the SCPI equivalent for multichannel addressed units

SYST:SAVE

where is an integer from 1 to 10.

Example:

*SAV 1

will save all the present settings to user setting location 1.

To recall settings:
*RCL

To save default settings:
*SDS

Note All parameters are saved and used when the user setting is recalled. Therefore, you