beautypg.com

Table b.3 commands for output control, Scpi command re fe rence scpi c o mman d summary – AMETEK HPD Series GPIB-Multichannel User Manual

Page 110

background image

106

Oper

ating

Manual

for Multichanne

l F
unctionality (

G

PIB-

M)

SCPI Command Re

fe

rence

SCPI C

o

mman

d Summary

Table B.3Commands for Output Control

Function

SCPI Command

Description

Query

Set (Immediate) Current
Setpoint

[[:]SOURce][]:CURRent[:LEVel][:IMMediate][:A

MPLitude] {|MAXimum|MINimum}

Change current setpoint

Yes

Set Triggered Current
Setpoint

[[:]SOURce][]:CURRent[:LEVel]:TRIGgered[:AMP

Litude] {|MAXimum|MINimum|DEFault}

Change triggered current setpoint

Yes

Set (Immediate) Voltage
Setpoint

[[:]SOURce][]:VOLTage[:LEVel][:IMMediate][:A

MPLitude] {|MAXimum|MINimum}

Change voltage setpoint

Yes

Set Triggered Voltage
Setpoint

[[:]SOURce][]:VOLTage[:LEVel]:TRIGgered[:AMP

Litude] {|MAXimum|MINimum|DEFault}

Change triggered votlage setpoint

Yes

Set Voltage Slew Rate
Voltage

[[:]SOURce][]:VOLTage:SLEW:STEP{

ltage>|MAXimum|MINimum|DEFault}

Sets the voltage slew rate voltage change
for the programmed time interval

Yes

Set Voltage Slew Rate
Interval

[[:]SOURce][]:VOLTage:SLEW:INTerval{

e-interval>|MAXimum|MINimum|DEFault}

Sets the voltage slew rate time interval for
the programmed voltage change

Yes

Set Over Current
Protection Level

[[:]SOURce][]:CURRent:PROTection[:OVER][:LEV

el] {|MAXimum|MINimum}

Set the over current protection level

Yes

Set Over Current
Protection
Shutdown State

[[:]SOURce][]:CURRent:PROTection[:OVER]:STAT

e

Select over current protection to
shutdown(ON) or set alarm (OFF)

Yes

Query Over Current
Protection Tripped

[[:]SOURce][]:CURRent:PROTection[:OVER]:TRIP

ped?

Query if over current protection mechanism
has tripped

N/A

Set Under Current
Protection Level

[[:]SOURce][]:CURRent:PROTection:UNDer[:LEVe

l] {|MAXimum|MINimum}

Set under current protection level

Yes

Set Under Current
Protection
Shutdown State

[[:]SOURce][]:CURRent:PROTection:UNDer:STATe

Select under current protection to shutdown
(ON) or set alarm (OFF)

Yes

Query Under Current
Protection Tripped

[[:]SOURce][]:CURRent:PROTection:UNDer:TRIPp

ed?

Query if under current protection
mechanism has tripped

N/A

Set Over Voltage
Protection Level

[[:]SOURce][]:VOLTage:PROTection[:OVER][:LEV

el] {|MAXimum|MINimum}

Set the over voltage protection level

Yes

Query Over Voltage
Protection Tripped

[SOURce][]:VOLTage:PROTection[:OVER]:TRIPped

?

Query if over voltage protection mechanism
has tripped

N/A

Set Under Voltage
Protection Level

[[:]SOURce][]:VOLTage:PROTection:UNDer[:LEVe

l] {|MAXimum|MINimum}

Set under voltage protection level

N/A

Set Under Voltage
Protection
Shutdown State

[[:]SOURce][]:VOLTage:PROTection:UNDer:STATe

Select under voltage protection to shutdown
(ON) or set alarm (OFF)

Yes

Query Under Voltage
Protection Tripped

[[:]SOURce][]:VOLTage:PROTection:UNDer:TRIPp

ed?

Query if under voltage protection
mechanism has tripped

N/A

Set High Current Limit

[[:]SOURce][]:CURRent:LIMit:HIGH

{|MAXimum|MINimum}

Set upper limit of current setpoint range (soft
limits)

Yes

Set Low Current Limit

[[:]SOURce][]:CURRent:LIMit:LOW

{|MAXimum|MINimum}

Set lower limit of current setpoint range (soft
limits)

Yes