Page 42

background image

eZ80190 Development Kit
User Manual

eZ80Acclaim! Development Platform

UM014108-0810

38

Jumper J14

The J14 jumper connection controls the polarity of the Ring Indicator. See
Table 17.

For jumpers J15–J18, RS485 functionality is not available on the
eZ80190 Module. However, this functionality is available in other eZ80

®

devices.

Jumper J15

The J15 jumper connection controls the selection RS485 circuit along
with UART0. When the shunt is placed, the RS485 circuit is enabled. See
Table 18. RS485 functionality will be available in future eZ80

®

devices.

Table 17. J14—RI

Shunt
Status

Function

Affected Device

1–2

The Ring Indicator for UART1 is inverted.

UART1.

2–3

The Ring Indicator for UART1 is not inverted.

UART1.

Table 18. J15—RS485_1_EN*

Shunt
Status

Function

Affected Device

In

The RS485 circuit is enabled on UART0.

The UART0 CONSOLE interface and IrDA are
disabled.

IrDA, UART0 CONSOLE
interface, RS485 interface.

Out

The RS485 circuit is disabled on UART0.

IrDA, UART0 CONSOLE
interface, RS485 interface.

Note: *To enable the RS485 circuit, the corresponding IrDA/RS232 circuit must be disabled.