eZ80190 Development Kit
User Manual
UM014108-0810
Operational
Description
13
16
GND
17
A2
Bidirectional
Yes
18
A1
Bidirectional
Yes
19
A11
Bidirectional
Yes
20
A12
Bidirectional
Yes
21
A4
Bidirectional
Yes
22
A20
Bidirectional
Yes
23
A5
Bidirectional
Yes
24
A17
Bidirectional
Yes
25
DIS_ETH
Output
Low
No
26
EN_FLASH
Output
Low
No
27
A21
Bidirectional
Yes
28
V
DD
29
A22
Bidirectional
Yes
30
A23
Bidirectional
Yes
Table 2. eZ80Acclaim!
®
Development Platform
Peripheral Bus Connector Identification—JP1
1
(Continued)
Pin #
Symbol
Signal Direction
Active Level
eZ801900100ZCO
Signal
2
Notes:
1. For the sake of simplicity in describing the interface, Power and Ground nets are omitted from
this table. The entire interface is represented in the
eZ80190 Module Schematic Diagrams
on
pages 66 through 73.
2. The Power and Ground nets are connected directly to the eZ801900100ZCO device.
Additional note: external capacitive loads on RD, WR, IORQ, MREQ, D0–D7 and A0–A23 should
be below 10 pF to satisfy the timing requirements for the eZ80
®
CPU. All unused inputs should be
pulled to either V
DD
or GND, depending on their inactive levels to reduce power consumption and
to reduce noise sensitivity. To prevent EMI, the EZ80CLK output can be deactivated via software in
the eZ80F91’s Peripheral Power-Down Register.