Xtramus DApps-MPT V1.4 User Manual
Page 31
31
E-mail: [email protected]
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
D. Filter Test
This filter test should filter all packets with the same source MAC address and destination MAC Address.
For this test, test packet sent are all with the same source MAC address and destination MAC address
and the DUT should filter this kind of packet.
Perform filter test on DUT in layer2 with different speeds, mode and various configurations. The following
tasks transmit frames with same DA (destination address) and SA (source address).
PT2-FT-10H,
PT2-FT-10F,
PT2-FT-100H,
PT2-FT-100F,
PT2-FT-1G,
PT2-FT_FULL (Perform Layer 2 Filter Test by two groups with different media type such as 100Mbps
and 1000Mbps for DUT ports with different maximum speeds.)
E. CRC Error Test
CRC Checksum is registered at the end of Ethernet frame.
Perform CRC (Cyclic Redundancy Check) error test on DUT in layer2 with different speeds, mode and
various configurations for the last 4 bytes of CRC to be filtered. For normal DUT, frame with error CRC
should be filtered. The following tasks transmit frames with CRC errors
.
PT2-CRC-10H, (10Mbps, Half Duplex)
PT2-CRC-10F, (10Mbps, Full Duplex)
PT2-CRC-100H, (100Mbps, Half Duplex)
PT2-CRC-100F, (100Mbps, Full Duplex)
PT2-CRC-1G, (1Gbps, Full Duplex)
PT2-CRC-FULL (Perform Layer 2 CRC check test by two groups with different media type such as
100Mbps and 1000Mbps for DUT ports with different maximum speeds.)