beautypg.com

Flow control (fc) _ pt2-fc-full, A. media type, B. packet a->b – Xtramus DApps-MPT V1.4 User Manual

Page 172

background image


172

E-mail: [email protected]

Website: www.Xtramus.com

XTRAMUS TECHNOLOGIES

®

9.2.17. Flow Control (FC) _ PT2-FC-Full

Layer 2 Flow Control Full Performance Test. Perform Layer 2 Flow Control tests by two groups with

different Media Type such as 100Mbps and 1000Mbps for DUT ports with different maximum speeds.

A. Media Type

Custom: Clicking this button to pop up a window for scrolling down and selecting the media type

for Port A and B.

Minimum Waiting Time: DApps-MPT will halt at least for the Minimum Waiting Time you input

here during auto-negotiation process.

Media Type Waiting Timeout: If the time spent for auto-negotiation exceeds the Media Type

Waiting Timeout you set here, the test will stop and the test result will be fail.

Link up sequentially: DApps-MPT makes connections to ports sequentially (one-by-one).

Therefore, DUT’s Link LEDs will be ON in a one-by-one manner as well. If any problems happen

during the test, it will be suspended immediately. Users can identify which port is causing the

problem by ch

ecking DUT’s port LEDs.

Link Status Check: DApps-MPT will check all ports in this task are connected properly before test.
LED Check Setting: If the LED Check Reminder function is enabled, a Checking LED Display

window will pop up when you start the task.

This window can remind the user how DUT LEDs’

display should be during the task. You can set the information that will be displayed on Checking

LED Display window here on LED Check Setting field. Also, you can load the image file for DUT

LED as well. If DU

T’s LED is not displayed as it should be comparing to the image file displayed on

Checking LED Display window, the user can press the Fail button, or vice versa.

B. Packet A->B

This manual is related to the following products: