A. media type – Xtramus DApps-MPT V1.4 User Manual
Page 242
242
E-mail: [email protected]
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
9.2.27. Filter Test (FT) _ PT2-FT-100H (100Mbps, Half Duplex)
Layer 2 100Mbps Half Duplex Filter Performance Test transmit test streams with the same DA and SA
(Destination and Source MAC address) to see if DUT can filter this redundant packets.
A. Media Type
Media Type: By clicking the scroll-down menu, you can set the transmitting mode to Auto (with
auto-negotiation), or Off (all the ports in this task are link-down).
Minimum Waiting Time: DApps-MPT will halt at least for the Minimum Waiting Time you input
here during auto-negotiation process.
Media Type Waiting Timeout: If the time spent for auto-negotiation exceeds the Media Type
Waiting Timeout you set here, the test will stop and the test result will be fail.
Link up sequentially: DApps-MPT makes connections to ports sequentially (one-by-one).
Therefore, DUT’s Link LEDs will be ON in a one-by-one manner as well. If any problems happen
during the test, it will be suspended immediately. Users can identify which port is causing the
problem by checking DUT’s port LEDs.
Link Status Check: DApps-MPT will check all ports in this task are connected properly before test.
LED Check Setting: If the LED Check Reminder function is enabled, a Checking LED Display
win
dow will pop up when you start the task. This window can remind the user how DUT LEDs’
display should be during the task. You can set the information that will be displayed on Checking
LED Display window here on LED Check Setting field. Also, you can load the image file for DUT
LED as well. If DUT’s LED is not displayed as it should be comparing to the image file displayed on
Checking LED Display window, the user can press the Fail button, or vice versa.