Control interface – Tempest Tornado User Manual
Page 28

Tornado Enclosure User Manual
page
28
Control Interface
LED Indicators
Heater
ON (Green)
Heater is ON, to maintain lower temperature
level or to prevent condensation
Fan
ON (Green)
Lamp is ON, or Temperature is HIGH and
Fan is cooling enclosure. Short burst when lamp
off indicates fan moving air to stabilize
temp/humidity
Lamp On
ON (Green)
Current sensing shows lamp is ON
Lamp hour counter is running
OFF
Current sensing shows lamp is OFF
Lamp hour counter is not running
Lamp Relay
ON (Green)
Lamp relay is closed (normal)
Luminaire power receptacle is energized
ON (Red)
Lamp relay is open due to over-temperature
event. Luminaire power receptacle is isolated.
Temp
FLASHING
(Green)
Temperature is below lower temp setting
ON (Green)
Temperature is in normal range
ON (Amber)
Humidity is above target limit
ON (Red)
Temperature is above top setting
FLASHING (Red)
Temperature is above Trip level
Luminaire power is isolated
DMX
OFF
DEC3.3 is in BASIC Mode – DMX not used. OR
DEC3.3 is in Monitor or Control Mode and no
valid DMX or RDM packet has been detected.
ON (GREEN)
Good DMX or RDM data packet received.
ON (RED)
Control Mode: DMX Fail. A previously good DMX
signal has failed.
Monitor Mode: No RDM information being
received (this is normal)