Wiring and control, Conduit entry holes, 3 wiring and control – Tempest Tornado User Manual
Page 17
Cyclone Enclosure User Manual
page 17
3 Wiring and Control
All electrical
work must be carried out by a properly licensed electrician, in compliance with
local electrical standards. Failure to observe this point will void the factory warranty for the Tempest
Enclosure.
1
Switch off power to the branch circuit, carefully following lockout and tag-out procedures. Failure to do so
could cause serious injury or death.
2
You will need two electrical junction boxes, located within a short distance from the enclosure, one for power,
one for DMX control. Use outdoor-rated flexible conduit between the box and the enclosure.
3
AC and control circuits must be wired in separate conduits.
Conduit entry holes
Power and DMX conduit entries
The conduit entry holes accept US ½” conduit fittings, and
international 20-22mm (OD) conduit fittings.
For temporary installations, use a suitable cable and clamp in the
same openings.
AC
Power
DMX
Control
Flexible Conduit
120VAC, or
208VAC
or 230VAC
Lighting
Control
AC Power
DMX Control
Ø 0.875”
22.2mm