3 Wiring and Control



All electrical

work must be carried out by a properly licensed electrician, in compliance with

local electrical standards. Failure to observe this point will void the factory warranty for the Tempest
Enclosure.

1

Switch off power to the branch circuit, carefully following lockout and tag-out procedures. Failure to do so
could cause serious injury or death.

2

You will need two electrical junction boxes, located within a short distance from the enclosure, one for power,
one for DMX control. Use outdoor-rated flexible conduit between the box and the enclosure.

3

AC and control circuits must be wired in separate conduits.

Conduit entry holes

Power and DMX conduit entries

The conduit entry holes accept US ½” conduit fittings, and

international 20-22mm (OD) conduit fittings.

For temporary installations, use a suitable cable and clamp in the

same openings.

AC

Power

DMX
Control

Flexible Conduit

120VAC, or

208VAC
or 230VAC

Lighting
Control

AC Power

DMX Control

Ø 0.875”
22.2mm