Start-up validation, Dmx connections – Tempest Tornado User Manual
Page 25

Cyclone Enclosure User Manual
page 25
without changing the air in the enclosure. Lamp on point may be set in 0.2 Amp
increments between 0.2 Amps and 2.0 Amps.
Start-up Validation
When you switch power ON to the DEC3.3 controller (firmware 01.00.006 and up), the following
indications will confirm that the major system elements are working correctly:
BEEP! – a loud beep indicates that the processor has initialized and is functioning
correctly.
FANS – fans run for three seconds
HEATER – the heater turns on for 15 seconds. This is enough to get warm to the touch.
DMX Connections
DMX refers to USITT DMX512, a commonly used control protocol in the entertainment industry,
running over RS485. Consult USITT DMX installation guidelines when laying out a system, or
employ a qualified DMX system integrator.
A DMX network will be required if:
a) The luminaire inside the enclosure requires a DMX control signal
b) You wish to monitor the enclosure using RDM
c) You wish to control the enclosure lamp relay over DMX
DMX Terminations
Note: DMX will not normally be used in
luminaire installations.
Pinout: (1) Ground, (2) Data -, (3) Data +.
DMX Connectors:
1
DMX IN from network
2
DMX OUT to luminaire (or to network
if not controlling luminaire)
3
DMX IN from luminaire
4
DMX OUT to network
DMX IN from
outside world
DMX OUT to
next DMX device
❹ ❸ ❷ ❶