beautypg.com

Paxton Superchargers 5.7L Dodge Hemi User Manual

Page 24

background image

2

P/N: 4809650

©2004 Paxton Automotive

All Rights Reserved, Intl. Copr. Secured

11NOV04 v1.0 03DodgeHemi(4809650v1.0)

I.

Locate the air intake temperature sensor pre-

viously removed, install into the unthreaded

bung on the 180° inlet elbow. Locate the air

temperature sensor factory plug, strip back

the tape to expose the wires and cut the

wires approximately 3" from the connector

plug. Using the supplied 12" length of wires

extend the connector plug to reach the relo-

cated air temperature sensor.

*** NOTE ***

It is recommended that these wire connections be

soldered and heat shrink used to insulate the con-

nections to ensure the best contact.

J.

Cut 2" off the short end of a supplied 3/4"

90° elbow hose. Attach the cut end onto the

oil fill neck breather barb. Install a supplied

3/4" hose mender into the open end of the

installed elbow hose.

K.

Cut a 13" long section of the supplied

straight 3/4" hose and connect one end onto

the hose mender previously installed, con-

nect the opposite end onto the 3/4" 90° hose

barb previously installed into the supplied

180° air inlet duct.

L.

Tighten all hose clamps.

Fig. 7-c