Selftest – Dataman 848Pro2 User Manual
Page 10

10
Selftest
Warning:
Selftest can be run in engineering mode only.
This mode is available only when external display, keyboard and mouse are connected
to DATAMAN-848PRO2.
If you feel that your programmer does not react according to your expectation, please
run the programmer (ISP connector’s) selftest using Diagnostic POD (Diagnostic POD
for ISP connectors #2), enclosed width the standard delivery package.
Selftest of programmer
Insert 48 pin diagnostic POD - type I into ZIF socket of the programmer. Take care
about orientation of 48 pin diagnostic POD - type I (see top side of POD).
Run selftest of programmer in PG4UW (Programmer / Selftest plus).
Selftest of ISP connector
Insert Diagnostic POD for ISP connectors #2 into ZIF socket of the programmer.
Take care about orientation of Diagnostic POD for ISP connectors #2.
Interconnect the 20 pins connector of Diagnostic POD for ISP connectors #2 with
the ISP connector of the programmer with the ISP cable included in delivery with the
programmer package. Be sure that the pins are interconnected properly (i.e. 1-1, 2-
2, ..., 20-20).
Run selftest of ISP connector in PG4UW (Programmer / Selftest ISP connector…).