d&b D12 Software User Manual
Page 30
Power Supply
Power Supply
Back
Mains
230V
Frequency 50Hz
Power Supply
Selecting "Power Supply" and pressing the encoder enters the submenu.
Mains
The currently measured mains voltage to which the device is connected
in volts. The typical accuracy is 2 %.
Frequency
The detected mains frequency.
Buzzer off
Buzzer
An additional acoustical signal for error messages.
on/off
Turning the buzzer on or off.
TSM Detection on
TSM Detection (Top/Sub-Mismatch)
NOTICE
The "TSM Detection" is set to "on" by factory default. If it is changed to
"off" this setting is kept also after the D12 has been powered off.
In "Dual channel mode" all four pins (TOP and SUB pins) of the output
connectors are driven. This could cause damage to TOPs when a SUB
configuration is selected on the respective channel.
The D12 monitors the current through the different output pins and
detects if a wrong cabinet type is connected.
The error message "Top/Sub-Mismatch" is displayed on the LCD and
the respective channel is muted.
If the pin assignment of the used wiring differs from the d&b standard,
"TSM Detection" can be set to "off" in order to avoid the detection of
an error.
D12 Software manual (Firmware V2.x.x)
(5.5 EN)
Page 30 of 36