AmpPreset

D12 amplifiers from firmware version V2.12 provide AmpPresets which
contain all important user settings of the entire device such as input,
output and channel configurations, EQ and delay settings.

Using the D12 AmpPresets a sound system can be operated in different
configurations (e.g. "Conference", "Music" or "Emergency Call") without
the need of transmitting all detailed settings of the devices used.

There are three types of AmpPreset memories:
User: Nine AmpPresets which can be accessed locally or via the d&b
Remote network (R10 Service software from V1.0.6). These AmpPresets
are used to set the complete D12 to a previously defined configuration
for a particular application and can be named individually.
Alarm: Three AmpPresets which can only be accessed via the d&b
Remote network (R10 Service software from V1.0.6). Intended for use in
alarm systems to protect the system settings against local modifications.
Backup: Three AmpPresets which can only be accessed via the d&b
Remote network (R10 Service software from V1.0.6). Intended for
temporary use to back up the current system settings when another
AmpPreset is loaded.

AmpPreset 1

AmpPreset

Last

1

*

Back

Select

9

Preset Name

Recall

Store

Clear

AmpPreset

Last

1

*

Back

Select

9

MyPreset

Recall

Store

Clear

Ok?

Recall

Store

Clear Ok!

AmpPreset

Last

1

Back

Select

9

(empty)

- - - -

Store Clear

*

Selecting "AmpPreset" and pushing the encoder enters the submenu.

The D12 menu item AmpPreset indicates the last AmpPreset number
loaded and is marked by a " " if any setting has been modified since
loading. The menu below provides the functions Select, Recall, Store,
Clear and a name field to manage the AmpPresets.

Select
Turning and pushing the encoder provides access to the nine user preset
memories to be loaded, saved or cleared.

To load, save or clear the selected AmpPreset first scroll to the
respective menu item (Recall, Store or Clear) and press the encoder to
select the desired function. "O.k.?" appears (flashing) to confirm the
selected function.

Recall
Recall the settings of a stored AmpPreset.

Store
Store the current amplifier settings in the selected preset memory and
name it.

Clear
The selected AmpPreset memory is cleared and "empty" is displayed.