Calibrate

NOTICE: Ensure that all components of the system are wired and

working correctly before executing the calibration!

Selecting "Calibrate Now" enters the submenu "Calib. Load
Monitoring" and the following message will be given as a precautionary
measure:

Calib. Load Monitoring

Cancel

A

Calibrate

Calibration interrupts
your audio program!

Calib. Load Monitoring

Cancel

A

Pilot Signal LF
+ 0.0dBu

Calib. Load Monitoring

Ok

A

Finished
LF 9.1 HF 16.0

Selecting "Calibrate" starts the calibration procedure while the progress
of the procedure is displayed. It can be canceled/interrupted and
restarted at any time by pushing the encoder during the procedure.

After a successful calibration the reference values are displayed and
"Ok" appears in the bottom line of the calibration screen.

Confirm to get back to the Load Monitoring menu.

If the calibration was not successful a respective error message will be
displayed. Also refer to section 2.5.2 System Check, Load and Input
Monitoring on page 32.

Reset of Load Monitoring errors

To reset error indications either:
- Power Off/On on the device or remotely.
- Switch Load Monitoring Off/On on the device or remotely.

Frequency Generator

Freq. Generator off

Frequency Generator

A

Back

Mode off

Level

-42.0dBu

Frequency 1000Hz

Frequency Generators

are used by

Load Monitoring

Ok

Each amplifier channel is equipped with an independent signal
generator offering pink noise or a sine wave signal.

The generator can be used to check the connected loudspeakers or to
identify room resonances, for example. The generator is inserted in the
signal path after the delay and before the loudspeaker equalization.
The test tone will sum with any input signal present.

Notes:

As a precautionary measure the frequency generator will
always be off (Mode = off) after the D12 is powered on.

The frequency generator provides the Pilot Signals for the
"Load

Monitoring"

function.

When

using

"Load

Monitoring" the frequency generator function is not
available and a message is given as shown in the graphic
opposite.

Mode

D12 Stage right

Q7

-3.0dB

-3.0dB

CUT HFA

EQ 0.01 CSA

EQ

Q-SUB

+0.0dB

D

P

100

Selecting "Mode" and pushing the encoder allows the following settings:

off:

generator off.

Sine:

sine wave generator (indicated as " " on the main screen).

Pink:

pink noise generator (indicated as " " on the main screen).