Relay (low voltage) – CUE ipCUE User Manual
Page 28
7.13. RELAY (Low Voltage)
This port provides one isolated low voltage relay. Normally Close and Normally Open contacts as well as
Common contact of each relay can be used. The Normally Close position is the state of the relay when it is not
turned on (energized). Each relay contact closure is rated 24 V / 0.5 A.
Relay output is applicable as follows
•
RELAY 1 – 2 (formerly AUX 1 - 2) for ipCUE-alpha, ipCUE-gamma
•
RELAY 1 – 8 (formerly AUX 1 - 8) for ipCUE-epsilon
•
RELAY 1 – 16 (formerly AUX 1 - 16) for ipCUE-delta
and not applicable for ipCUE-beta and ipCUE-sigma.
Connector pin out
Note: NC-C-NO description
User Manual ipCUE Controllers
Page 28 of 52
RELAY
Pin
NC
C
NO
3-pin 3.5 mm
Description
Relay Contact Common
Relay Contact Normal Close
Relay Contact Normal Open
NC C NO
Close RELAY inside ipCUE
Open RELAY inside ipCUE
NC
C
NO