Ir/serial – CUE ipCUE User Manual
Page 24
7.9.
IR/SERIAL
IR/Serial output is applicable as follows
•
IR/SERIAL 1 – 8 on ipCUE-alpha, ipCUE-beta, ipCUE-delta, ipCUE-epsilon
•
IR/SERIAL 1 – 3 on ipCUE-sigma
•
IR/SERIAL 1 – 2 on ipCUE-gamma.
This type of port provides
•
Output for infra-red emitters (IR Adapter /i), maximum IR output rate is 1.2 MHz.
•
RS-232 serial output (one way), maximum serial data rate is 115 200 Bd (bps), output signal levels for
RS-232 are in the -12 V to +12 V range.
The IR outputs and RS-232 outputs can be combined on independent outputs (for example three outputs can
be used as IR, five outputs can be used as RS-232).
Connector pin out
Notes
•
All pins labeled G are connected together.
•
Up to three original infra-red emitters IR Adapter /i can be connected to each output in parallel.
•
Up to ten IR Sprayers can be connected to each output in parallel
•
It is not recommended to connect more infra-red emitters of various manufacturers in parallel because
the output can be either overloaded or damaged.
User Manual ipCUE Controllers
Page 24 of 52
Pin
G
S
IR/SERIAL
2-pin 3.5 mm
Description
Ground
IR/Serial Signal (Output)
S G