SMS-MULTI-IO
- 33 -
mode com
4
4
4
4
Data=8 Parity=n Baud=115200 DTR=OFF RTS=OFF
AVROSP -dATxmega128A1 -e -ifSMS-MULTI-IO.hex -pf -vf -cCOM
4
4
4
4
del ATxmega128A1.xml
•
Replace the two comport numbers with the obtained comport number.
•
Save and exit the ‘Fw_SMS-MULTI-IO.bat’.
•
Double click the ‘Fw_SMS-MULTI-IO.bat’ to run.
•
DOSPromt opens and performs the bootloader, this takes about 2 minutes.
•
When finished remove the jumper and restart the module.