Signals

Direction

Width (Bit)

Description

clr

Input

1

The asynchronous clear signal. When you assert the

clr

signal, the IP core sets the

tsdcalo[7:0]

signal

to

11010101

(

0xD5

) and the

tsdcaldone

signal to

0

.

This is an active-high signal. By default, this port

connects to GND.

tsdcalo[7:0]

Output

8

8-bit output signal that contains the analog-to-

digital-conversion temperature value. The 8-bit

value maps to a unique temperature value. During

device power-up or when you assert the

clr

signal,

the IP core sets the

tsdcalo[7:0]

to

11010101

(

0xD5

).

tsdcaldone

Output

1

This signal indicates the completion of the tempera‐

ture sensing process. The IP core asserts this signal

when the process is complete. During device power-

up or when you assert the

clr

signal, the IP core sets

the

tsdcaldone

to

0

.

Table 6: The Mapping of tsdcalo [7..0] Value to Arria V, Arria V GZ, Stratix IV, and Stratix V Devices

Temperature

This table shows the value of

tsdcalo[7:0]

that corresponds to the device temperature range. The temperature

specification ranges from -70° C to 127° C.

Value of tsdcalo[7:0] in Hexadecimal

Temperature in Degree Celsius (°C)

FF

127

...

...

E4

100

...

...

D5

85

...

...

D0

80

...

...

B2

50

...

...

9E

30

...

...

8A

10

...

...

80

0

...

...

76

-10