Verilog hdl prototype, Vhdl component declaration, Document revision history – Altera Temperature Sensor User Manual
Page 10

Value of tsdcalo[7:0] in Hexadecimal
Temperature in Degree Celsius (°C)
...
...
6C
-20
...
...
62
-30
...
...
4E
-50
...
...
3A
-70° C
Altera Temperature Sensor Prototypes and Component Declarations
Verilog HDL Prototype
The Verilog HDL prototype is located in the
VHDL Component Declaration
The VHDL component declaration is located in the
\altera_mf\ directoryaltera_mf_components.vhd.
Document Revision History
This table lists the changes made to the document.
Table 7: Document Revision History
Date
Document
Version
Changes Made
May 2015
2015.05.04 • Added a link on how to calculate the temperature from the
tempout[9:0]
value.
• Editorial updates.
December 2014
2014.12.15 • Added Arria 10, Arria V, and Arria V GZ devices to the Device
Support section.
• Editorial changes to the warning message in Temperature
Sensing Operation section.
• Added Arria 10 devices information.
• Updated template.
10
Altera Temperature Sensor Prototypes and Component Declarations
UG-01074
2015.05.04
Altera Corporation
Altera Temperature Sensor IP Core User Guide